Use this glossary to decode a window drawing, energy label, quote, inspection or warranty. It separates component properties from whole-window ratings, water-vapour calculations from frost predictions, and product certification from the performance of an installed building. Definitions include the limitations that matter when choosing or caring for a window in Canada.
Canadian planning context. Technical examples from other regions are identified in the guide; approval and performance requirements must be checked for the actual building and jurisdiction. Original explanatory diagrams are not construction details.
- Identify the assembly, units, test method and conditions before comparing any rating.
- Air control, water drainage, vapour diffusion and structural support are different jobs at an opening.
- Pane count, frame material and coating names cannot replace the actual product specification.
- A dew-point threshold describes saturation over liquid water; it is not a healthy humidity target or frost forecast.
- Keep the product identity, approved scope, drawings and written remedies together for future service.
01 /Find the word, then follow its boundary
Terms appear alphabetically below. A word such as seal can describe a glazing-cavity edge, a glazing gasket or the frame-to-wall connection; these have different functions and remedies. Match the definition to the drawing, product record and observed location before deciding what failed.
For calculations, use the U-factor and R-value lab and measured-surface moisture lab. For test designations, follow wind, water and air ratings and acoustic ratings. The labs explain their assumptions and do not convert a comparison into a bill forecast, health recommendation or product certification.
For a project, turn the vocabulary into a window specification schedule and keep the labels, certificates and submittals. Use the budget planner with your written quote amounts. The glossary adds no market prices or automatic material and glazing premiums.
A–ZTerms
- Absorptance
- The fraction of incident energy absorbed by a material, distinct from the fractions reflected and transmitted. Specify whether the discussion concerns sunlight, visible light or long-wave radiation. Absorbed solar energy can warm glass and contribute to inward heat flow and thermal-stress assessment.
- Acoustic interlayer
- A laminate interlayer designed for acoustic damping. Its effect depends on formulation, temperature, pane thicknesses and the complete assembly. It is a component description, not an STC or OITC result; obtain the tested glazing and window construction for the relevant noise spectrum.
- Aerogel glazing
- A glazing concept using a highly porous insulating material, with products varying in transparency, light diffusion, thickness and construction. Distinguish a research prototype from an available certified assembly. Check optical quality, whole-window data, edge durability, repair arrangements and Canadian project acceptance.
- Air barrier
- A continuous layer or connected system limiting uncontrolled airflow through the building enclosure. The window must connect to it at the perimeter. An air barrier is not necessarily the same material as the vapour retarder or the exterior water-resistive barrier.
- Air leakage
- Air passing through a closed assembly under a stated pressure difference, usually reported in L/s/m² in Canada. Compare pressure, direction, specimen size and test method. Canadian ENERGY STAR version 5 requires both infiltration and exfiltration no greater than 1.5 L/s/m²; that label does not test the installed wall joint.
- Aluminum-clad wood
- A subtype of clad-wood construction using a wood substrate and aluminum exterior skin. Ask which components are clad and how joints, drainage and finishes are detailed; the material name does not determine price.
- Anchorage
- The connections transferring window loads to an appropriate structural substrate. Fasteners, spacing, edge distances and reinforcement are design details. Trim, sealant and insulating foam are not substitutes for the specified load path; changes in window size or assembly may require revised engineering.
- Annealed glass
- Glass cooled to relieve manufacturing stress without the strengthening treatment used for tempered or heat-strengthened glass. Its breakage characteristics differ from safety glazing. Annealed plies can form part of a tested laminate; the complete construction and location determine the required safety assessment.
- Annual sunlight exposure (ASE)
- A daylight-analysis metric counting the occupied area exposed to specified direct-sun illuminance for more than a specified annual duration. State the metric definition and modelling assumptions. It is an exposure indicator, not a complete glare assessment, cooling-load result or prediction of every occupant’s comfort.
- Anti-reflective coating
- A surface treatment intended to reduce reflected light in a specified wavelength range. It is different from a low-e coating and from a bird-visible pattern. Check the actual coating’s optical data, approved surface, cleaning method and durability rather than assuming every reflection-reducing product serves the same purpose.
- Argon
- A non-flammable inert gas used in the sealed glazing cavity to reduce heat transport compared with an otherwise similar air-filled cavity. Performance depends on concentration, gap, coatings and the complete assembly. Visible fog cannot measure the remaining argon concentration.
- Asymmetric glazing
- A glass assembly using unequal pane thicknesses or different constructions. Changing the panes changes their frequency response and can improve sound reduction for a particular noise spectrum. A thickness ratio found useful in one experiment is not a universal specification; request the complete assembly’s measured results.
- Awning window
- A top-hinged sash that opens outward at the bottom. The operating direction can offer some shelter during light rain, but an open sash is not a rated watertight barrier. Opening limits, wind, screens, hardware and safe reach affect its use.
- Backer rod
- A round foam cord pushed into a joint before sealant is applied. It controls sealant depth and lets the sealant bond to only two sides so it can stretch as the joint moves.
- Balance
- A spring, counterweight or related mechanism supporting a vertically moving sash. A failed balance can let the sash fall. Replacement requires the correct weight range, hardware and procedure; support the sash and follow the manufacturer’s service instructions.
- Bay window
- An angled projecting assembly, commonly a centre window with two side units. Its weight, support, roof, seat, joints and wall transitions must be designed together. A collection of individually rated windows does not establish the structural capacity or water performance of the combined bay.
- Bird-visible pattern
- A treatment intended to make glazing apparent to birds across the hazard area. Pattern spacing, contrast, exterior visibility and actual installation matter. ECCC guidance favours closely spaced exterior markings; a few silhouettes, ordinary insect screens in the wrong location or an energy label do not establish effectiveness.
- Blocking
- Solid support placed where a load or attachment needs a suitable bearing surface. Identify whether the detail supports a frame, mullion, fastener or adjacent cladding. Its dimensions and moisture durability belong to the structural and enclosure design, not an installer’s improvised gap-filling choice.
- Bow window
- A curved projecting assembly of several window units. The number and angles vary by design. Confirm the support system, unit connections, roof or head, seat insulation and drainage rather than treating the bow as an ordinary flat replacement opening.
- Brickmould
- An exterior trim profile at the perimeter of a window. Its shape and attachment vary. It can cover a joint but does not by itself form a continuous drainage or air-control connection to the wall; concealed flashing and weather-barrier laps still matter.
- Capillary break
- A discontinuity that interrupts water movement by capillary action between closely spaced surfaces. A drained gap or suitable separation can serve this purpose in a designed detail. It differs from an air seal; preventing capillary transfer does not address every rain, pressure or leakage path.
- Capping
- Aluminum or vinyl sheet bent on site to cover the old frame, sill and brickmould outside. It is a cladding, not a flashing; water management behind it still matters.
- Casement window
- A side-hinged sash that swings outward or inward, depending on the system. Some use crank operators and compression seals. Compare actual air-leakage ratings and hardware condition rather than assuming every casement outperforms every sliding product.
- Centre-of-glass value
- A property assigned to the glazing area away from the frame and edge, often written Ug for thermal transmittance. It can help compare glass make-ups, but excludes important perimeter components. Do not compare a centre-glass figure directly with a certified whole-window figure as if their scopes matched.
- Change order
- A written amendment describing a change to the agreed work, price or schedule. Record the reason, scope, approvals and consequences before the changed work proceeds where practicable. A verbal instruction or informal observation does not describe the revised contractual responsibilities clearly.
- Clad wood
- Wood-based window construction with an exterior protective skin. Aluminum-clad wood is one subtype; other claddings may use vinyl or other materials.
- Clear opening
- The unobstructed opening available in the required operating condition, distinct from the frame, sash or rough-opening dimensions. Hardware, screens and opening controls can reduce it. Emergency escape also depends on operation, access and local requirements; area alone is not a complete compliance check.
- Clerestory
- A high-level window band admitting daylight above the normal eye line. It can bring light deeper into a room, but orientation, roof geometry, shading and controls determine the result. Plan maintenance access, operability and solar exposure instead of judging it only from its elevation.
- Coincidence dip
- A reduction in sound transmission loss over a frequency region where a pane’s bending behaviour couples efficiently with incident sound. The position and depth depend on construction. Acoustic laminates and unequal panes can change the response, but no single pane feature establishes the final window rating.
- Composite frame
- A frame made from blended materials, such as resin with wood or mineral fibre. Recipes vary widely, so ask exactly what a 'composite' frame is made of.
- Condensation Index (CI)
- An NFRC condensation metric with a method distinct from the older Condensation Resistance rating. Read the applicable method, specimen and scope before comparing values. NFRC’s CI information explains its relationship to cold-surface assessment; identical-looking numbers from different indices are not interchangeable.
- Condensation resistance
- A tested or calculated description of surface-temperature behaviour under specified conditions. Different methods use different indices and reference points. It does not predict every installed cold spot or prescribe a healthy indoor humidity level. See surface temperatures and dew point.
- Conduction
- Heat transport through material, or through a gas without treating bulk air movement as the transport mechanism. Window glass, frames and edge components conduct heat. Low-e coatings primarily address radiation, so improving one path does not eliminate the other paths.
- Convection
- Heat exchange associated with fluid motion, including room air moving along cold glass and circulation in a cavity. Air movement can be natural or forced. This surface or cavity behaviour differs from uncontrolled air leakage through a joint, which carries moisture and heat across the enclosure.
- Curtain wall
- A non-loadbearing exterior enclosure system supported by the building structure, commonly spanning in front of floor edges. Glass, framing, anchors, drainage and movement joints form the assembly. A replacement residential-window label is not a specification for a complete curtain wall.
- Desiccant
- A moisture-absorbing material in an insulating-glass edge system. It helps keep the sealed cavity dry. Capacity, seal condition and service exposure affect its performance; seeing cavity moisture does not identify the exact failed component or quantify gas loss.
- Design pressure (DP)
- The pressure used for specified structural-performance requirements or testing. Read the direction, test method and project loading basis. DP is not the same as a performance grade, and a pressure number alone does not establish water resistance, anchorage adequacy or acceptance at a particular building exposure.
- Dew point
- The temperature at which a given water-vapour pressure reaches saturation over liquid water. A room-side surface at or below it can support condensation under the stated conditions. Below freezing, saturation over ice and frost point are separate calculations; a liquid-water dew-point result does not predict icing.
- Differential movement
- Different amounts or directions of movement between adjacent components as temperature, moisture, loads or building position change. Window joints must accommodate the expected movement while retaining their intended control functions. Rigidly filling every gap can defeat a designed movement joint.
- Diffuse daylight
- Light arriving from the sky and surrounding surfaces without a single direct-sun beam. It can provide useful illumination with different glare and heat effects from direct sun. Overcast skies, nearby obstructions, glazing properties and room surfaces influence how much reaches the occupied space.
- Double glazing
- Two panes separated by one cavity in a glazing assembly. The cavity may contain air or a specified gas, and coatings are optional. Pane count alone does not establish U-factor, acoustics, safety, gas concentration or price; identify the complete construction.
- Double-hung window
- A window with two sashes that both slide vertically. Many tilt inward for cleaning. A single-hung window has only the lower sash moving.
- Drainage plane
- The connected surface or layer intended to carry incidental water toward a safe outlet. Window flashing must join it with the correct laps and discharge path. The drainage plane can sit behind cladding; a neatly finished exterior trim joint does not show whether that concealed connection works.
- Drip cap
- A metal or vinyl flashing across the top of a window that sheds water away from the frame. The weather barrier above laps over it.
- Edge seal
- The perimeter sealing system maintaining the intended conditions inside an insulating-glass cavity. Some systems use separate primary and secondary functions. Compatibility, fabrication, exposure and glazing support matter; the seal is different from the perimeter seal between a window frame and the wall.
- Edge-of-glass region
- The glazing perimeter where the spacer, edge seals and frame affect heat flow and surface temperature. It often differs from the centre of a pane. A centre-glass infrared reading or rating cannot establish the coldest edge condition; inspect the actual location and measurement limitations.
- Egress window
- An opening used for emergency escape where the applicable rules allow or require it. Clear opening, minimum dimensions, operation, access and any window-well conditions must be checked together. Ask the local authority which current requirements apply to the particular bedroom and project.
- Electrochromic glazing
- Glazing that changes optical state through an electrically controlled process. Compare light transmission and solar gain for the specified states, along with control logic, power, wiring and service arrangements. A tinted appearance does not by itself establish thermal insulation or performance when controls fail.
- Emissivity
- A surface’s ability to emit thermal radiation relative to a reference ideal emitter under stated conditions. Low-e surfaces reduce long-wave radiative exchange. Emissivity is not visible transparency, solar reflectance or whole-window U-factor; those quantities describe different aspects of the assembly.
- End dam
- A raised or sealed termination intended to keep water from escaping sideways from a sill pan or flashing detail. Its height, continuity and connection to adjacent layers must suit the system. An end dam needs an outward discharge route rather than a fully trapped pocket.
- Energy Rating (ER)
- A Canadian index combining rated heat loss, air leakage and solar gain using specified reference conditions. Canadian ENERGY STAR version 5 offers an ER qualification path of at least 34. A higher ER is not a cooling, glare or orientation recommendation for every room.
- ENERGY STAR Most Efficient
- A dated recognition programme with criteria separate from ordinary ENERGY STAR certification. Confirm the recognition year, model identity and current NRCan listing. A historic designation does not establish eligibility for a current rebate, installation quality or the performance of a different glass package.
- Exterior condensation
- Moisture on the outdoor surface when that surface reaches the outdoor air’s saturation conditions. Radiative cooling can contribute, particularly under certain clear-sky conditions. The pattern may be normal, but its presence alone does not certify insulation quality; distinguish it from cavity moisture and leakage.
- Exterior shading
- A device outside the glazing that intercepts some sunlight before it reaches the glass. Overhangs, fins, screens and movable shades behave differently by orientation and sun angle. Check wind, snow, access and attachment as well as seasonal shading; no fixed shade controls every east or west sun exposure.
- Fenestration
- The building’s window, door, skylight and related glazed-opening systems. The exact scope can differ between a standard, programme or project specification. When a report gives a fenestration rating, establish which assembly types, components and boundary conditions it includes.
- Fibreglass frame
- A frame using glass-fibre-reinforced material; some products use pultruded profiles. Exact construction, finish, size limits and whole-window performance vary by series.
- Fixed window
- A window intended to remain closed, with no normal ventilation opening. Removing operable hardware can change sightlines and leakage paths, but glass area and air performance depend on the actual product. Fixed glazing cannot substitute for required ventilation or emergency escape without checking the project requirements.
- Flanking transmission
- Sound reaching the receiving space by paths other than the element being compared, such as adjacent walls, roof junctions or vents. These paths can limit the benefit of better glazing. A high laboratory window rating does not identify or remove every sound path in the installed façade.
- Flashing tape
- Self-adhered membrane used to seal and lap a window's edges or nailing fin to the wall's weather barrier. It must be compatible with the barrier and sealants and applied within its temperature limits.
- Frame U-factor
- Thermal transmittance assigned to the frame portion in a stated calculation method, often written Uf. Its area and connection to the glass edge influence whole-window performance. A frame-material name does not determine Uf, and the frame figure does not include the entire installation joint.
- Frost point
- The temperature at which a given water-vapour pressure reaches saturation over ice. It differs from the liquid-water dew point below freezing. Surface icing also depends on exposure and time; the moisture lab deliberately uses the liquid-water relation and does not calculate frost point.
- Full-frame replacement
- A replacement method removing the old window frame to the agreed opening boundary. The scope must define opening assessment, wall connections, air and water management, and restoration; actual prices depend on that scope.
- Garden window
- A small box-shaped window that projects outward, often over a kitchen sink, with glass on the sides and top and shelves inside.
- Gas concentration
- The measured or specified proportion of a cavity occupied by a particular gas. The relevant method and sampling point matter. Initial certification tests or accelerated ageing checks are not direct measurements of every installed unit years later; fog, colour or reflection counts cannot quantify the gas percentage.
- Glazing
- The glass in a window, or the act of installing it. 'Double glazing' and 'triple glazing' describe the number of panes.
- Glazing bead
- A removable or fixed retaining profile helping hold glazing in a frame or sash. Its location and fastening differ by system. A service technician needs the correct bead, seals and support arrangement; removing a bead can release heavy or unstable glass.
- Glazing gasket
- A shaped flexible seal at the glazing-to-frame interface. It may provide several sealing or support functions, depending on the system. Material compatibility, compression, corner details and replacement identity matter; a generic strip of similar appearance may not perform as the specified gasket.
- Glazing pocket
- The recess or channel receiving the glass edge in a frame or sash. It must accommodate the specified glass thickness, support, clearances and drainage. A thicker replacement unit is not suitable merely because its visible dimensions resemble the old pane.
- Grilles
- Decorative bars that divide the glass visually, also called muntins. They can sit on the glass surfaces or be sealed between the panes.
- Head
- The top horizontal member of a window frame. Also used for the top of the rough opening, where the header carries the load above.
- Heat recovery ventilator (HRV)
- A mechanical ventilation unit transferring part of the outgoing air’s heat to incoming air while exchanging air streams. Its design flow, balancing, filtration and frost-control strategy matter. Tighter replacement windows can change uncontrolled leakage; they do not replace the need to assess the ventilation system.
- Heat-strengthened glass
- Heat-treated glass with a stress level and breakage behaviour different from fully tempered glass. It can be appropriate in specified glazing designs but is not automatically safety glazing. A laminate using heat-strengthened plies must be assessed as its complete tested construction.
- Heating degree-days
- A weather index adding the daily temperature shortfalls below a stated reference temperature over a stated period. The base must be identified; 18°C is one common Canadian convention. Degree-days describe climate exposure, not a building’s exact heating demand or the savings from replacing its windows.
- Hopper window
- A window hinged at the bottom that tilts inward from the top. Common in basements.
- Imperial U-factor
- Thermal transmittance expressed in Btu/h·ft²·°F. Convert it to SI by multiplying by approximately 5.678263. Record the units before comparing labels: the same numerical value in SI and imperial units represents different heat transfer. Use the rating lab for matched-scope conversions.
- Insert replacement
- A new window fitted within retained portions of an existing frame. Also called pocket or retrofit replacement in some quotations. Define exactly what stays and what is removed. Retained framing, reduced glass area and the concealed wall connection can affect durability, clear opening and cost.
- Installation thermal bridge
- Additional heat flow associated with the junction between the window and surrounding wall. Frame position, adjacent insulation and connection geometry influence it. A certified product’s U-factor does not establish this junction’s performance; demanding projects may require a separately modelled installation detail.
- Insulating glass unit (IGU)
- A perimeter-sealed multi-pane glazing unit with one or more cavities. Glass, coatings, gas, spacer, desiccant and edge seals form the system. It is a component of a window: its centre-glass data is not the complete frame-and-sash rating.
- Interior surface resistance
- The resistance associated with heat exchange at the room-side surface under a stated calculation convention. It depends on the adopted boundary assumptions and actual conditions. Using a teaching value to infer a glass temperature does not create a certified condensation rating or model every curtain and airflow condition.
- Interstitial condensation
- Moisture condensing within a construction rather than on a readily visible room or outdoor surface. Air leakage, vapour movement, temperatures and drying paths must be considered together. Surface dryness does not establish that the concealed window-to-wall junction is dry.
- Jamb
- Each vertical side member of a window frame. Also the sides of the rough opening.
- Krypton
- An inert cavity gas that can be useful in some narrow-gap insulating-glass designs. Suitability depends on the specified gap, concentration and complete make-up. The gas name does not establish a whole-window rating, a field service life or a standard price premium.
- Laminated glass
- Glass plies bonded by one or more interlayers that can retain fragments after breakage. Safety, acoustic, ultraviolet and security performance depend on the construction and relevant testing. Laminated glass is not automatically a fall barrier or a certified forced-entry assembly.
- Linear thermal transmittance (psi)
- Additional heat transfer per unit length and temperature difference assigned to a defined junction, commonly W/m·K. The reference geometry and calculation conventions matter. Edge-of-glass psi and installation psi describe different boundaries; avoid adding or comparing them without matching their definitions.
- Lintel
- The beam, often a steel angle in brick walls, that carries the masonry over a window opening. Rusting lintels can crack the brick above.
- Low-e coating
- A coating designed to reduce long-wave radiative heat exchange at a glass surface. Solar gain, visible light, colour and reflectance depend on the particular coating and glazing make-up. Number the surfaces and specify the manufacturer-approved placement rather than choosing by the low-e label alone.
- Low-expansion foam
- A foam product intended for compatible window or door perimeter joints. It may insulate a gap, but pressure, curing, substrate preparation and joint movement still matter. Follow the specified system: foam alone does not necessarily provide the required continuous air seal or drained water connection.
- Material Threat Factor
- A bird-collision test metric expressing results under a particular controlled method. It is useful within that method’s scope, but is not the observed percentage of collisions at every building. Reflections, lighting, habitat, pattern coverage and installation can change field outcomes.
- Mechanical ventilation
- Planned air exchange driven by fans, which can supply air, exhaust air or provide a balanced system. Flow, distribution, operation and maintenance affect results. Opening a window can supplement ventilation when conditions permit, but is not a dependable substitute for every required design flow.
- Mock-up
- A representative sample assembly constructed or installed to agree appearance, detailing, procedure or test performance before wider work. Define what the mock-up demonstrates and whether it remains in the building. Acceptance of its colour or workmanship is not acceptance of every untested performance claim.
- Mullion
- A dividing structural or framing member between adjacent glazed areas or window units. Factory and site-mulled assemblies can have different support and testing arrangements. Ask how the combined assembly is reinforced, anchored and drained; individual window labels do not establish the mulled connection’s capacity.
- NAFS
- The North American Fenestration Standard, AAMA/WDMA/CSA 101/I.S.2/A440, covering specified product-performance testing and classification. Read the edition, operator, class, grade and tested dimensions. The Canadian Supplement and locally adopted rules also matter; publication of a new edition is not evidence of local adoption.
- Nailing fin
- A perimeter flange on some window systems used for attachment and connection to the wall’s water-control layers. Fastener location, structural substrate, sealant and flashing sequence are system-specific. A fin does not replace required structural anchorage, and not every replacement system has one.
- OITC (Outdoor-Indoor Transmission Class)
- A single-number acoustic rating calculated using a defined outdoor transportation-noise reference spectrum. It incorporates lower-frequency bands than STC, but a given OITC does not describe every traffic, aircraft or industrial source. Compare complete specimen constructions and frequency-band data for demanding noise problems.
- Operator
- A mechanism that moves an operable sash, such as a crank or lever assembly. Correct part identification, sash weight, adjustment and weatherstrip condition matter. A replacement operator does not repair a distorted frame, an unsafe opening or every cause of a poor seal.
- Overheating
- An indoor condition in which heat exposure exceeds the comfort or assessment criterion being used. Glazing area, solar gain, shading, ventilation, internal gains and weather interact. State the chosen criterion and occupied period; a low winter U-factor does not establish summer comfort.
- Passive House component certification
- Assessment of a component under a named certification programme and climate scope. Passive House Institute and Phius use different programmes and data conventions. Component certification does not certify the entire building, establish local code acceptance or rate an unspecified installation junction.
- Performance grade (PG)
- A NAFS designation associated with meeting the required structural, water and air performance criteria for a stated operator, class and specimen. It is broader than design pressure alone. Check the actual designation, dimensions and referenced edition rather than reading PG as a universal building-height approval.
- Perimeter seal
- A seal at a specified boundary, often the frame-to-opening joint. The term is incomplete unless the drawing identifies the location, material, substrate and function. An interior air seal and exterior weather joint can have different requirements, and the intended drainage path must stay usable.
- Prepaid contracting licence
- An Alberta business licence relevant to specified prepaid contracts negotiated or concluded in person away from the seller’s business premises. The official provincial page explains applicability and exemptions. Check the legal business identity and current status; holding this licence is not a product or workmanship certification.
- Product identifier
- A model, series, option code or other record linking the purchased assembly to its technical information. A brand name alone is rarely enough. Retain the glass make-up, operating type, size, label photographs and order documentation so later repairs and claims can identify the actual product.
- R-value
- Thermal resistance in a stated unit system and for a defined assembly. For matched scope, resistance is the reciprocal of thermal transmittance after converting units. An imperial window R derived from an SI U-factor equals approximately 5.678263 divided by that U; centre-glass R is not whole-window R.
- Relative humidity (RH)
- Water-vapour pressure expressed as a percentage of saturation pressure at the air’s temperature and stated convention. Temperature changes can alter RH without adding moisture. Compare a measured RH with its temperature, sensor location and uncertainty; a window’s saturation threshold is not a health or comfort target.
- Rough opening
- The opening in the wall prepared to receive a window or other assembly. Distinguish structural framing, masonry openings and finished trim dimensions. Replacement scope determines how much is exposed; the supplier’s verified order dimensions are not simply the homeowner’s approximate opening measurements.
- RSI value
- Thermal resistance expressed in m²·K/W. For the same assembly and conditions, RSI equals 1 divided by SI U-factor. Identify the scope and unit system rather than reading any R number as interchangeable with wall insulation data or an installed-junction assessment.
- Safety-glazing mark
- Identification associated with a tested safety-glazing construction and certification or compliance scope. Read the manufacturer, designation and referenced requirements. A mark can support product identification, but does not by itself establish that the glazing, frame, location and guard or security design satisfy every project requirement.
- Sash
- The part of a window that holds the glass and, on operable windows, moves. The frame surrounds it.
- Seal failure
- Loss of an insulating-glass edge system’s ability to maintain the intended cavity conditions. Persistent moisture confirmed between panes is evidence of a cavity problem, but surface deposits can resemble it. Diagnosis should identify the moisture location and product before choosing a repair or replacement component.
- Sealant compatibility
- The suitability of a sealant with the adjoining glass, coatings, gaskets, membranes, finishes and substrates. Chemical interaction, adhesion, staining, movement and exposure can matter. Use documented approved combinations and preparation procedures; similar colour or the word exterior does not establish compatibility.
- Secondary glazing
- An additional glazing assembly installed alongside an existing window. It may be interior or exterior, fixed or operable, depending on the design. Assess access, cavity moisture, cleaning, emergency escape and the original window’s drainage rather than assuming an extra pane is equivalent to replacing the sealed unit.
- Setting block
- A designated support transferring glazing weight within a frame or sash while maintaining required clearances. Its material, dimensions and position must suit the system and glass construction. Improvised packing can damage edges, obstruct drainage or change how the glass is loaded.
- Shim
- A support or positioning piece between the frame and the opening. Material, load-bearing points, spacing and attachment must follow the design. Shims position and transfer loads; filling a perimeter gap with foam does not replace the required structural support.
- Shop drawing
- A project-specific drawing translating the agreed assembly into dimensions, components, details and interfaces for review. Establish its approval status and revision. It complements the contract and specification; it is not automatically structural engineering or a substitute for verified order measurements.
- Sightline
- The visible width of framing or other components when viewed from a specified side or position. It affects glass area, view and architectural appearance. Compare drawings for the actual size and operation; a photograph of a large fixed window may conceal the framing proportions of a small operable one.
- Sill
- The lower horizontal member of a window frame, or the lower boundary of the opening when used in construction descriptions. Name which one is meant. Water staining here can originate higher up; its location alone does not identify the entry path.
- Sill pan
- A formed or membrane drainage detail at the bottom of an opening, designed to collect incidental water and discharge it outward. Back and end containment, slope, outlet and continuity matter. A sealed-looking tray with no usable drainage path is not a complete water-management detail.
- Slider
- A window whose sash moves horizontally in a track. The opening fraction, cleaning access, seals and drainage vary by design. Compare measured clear opening and certified performance; do not infer a fixed opening percentage or leakage rate from the operating name.
- Solar altitude
- The sun’s angle above the horizon at a stated place and time. Together with solar azimuth and window orientation, it helps explain when a shade intercepts direct sun. A high summer noon sun does not describe low-angle morning or evening exposure.
- Solar heat gain coefficient (SHGC)
- The fraction of incident solar energy admitted as heat under the rating conditions, including directly transmitted energy and the inward-flowing portion of absorbed energy. It ranges from 0 to 1. Choose it with orientation, shading, heating and overheating in mind; it is not visible transmittance.
- Solar reflectance
- The fraction of incident solar energy reflected under the stated measurement conditions. It differs from visible reflectance and long-wave emissivity. A shiny appearance does not quantify solar control, and reflectance alone does not account for inward heat from energy absorbed by the glazing.
- Solar-control coating
- A coating intended to reduce admitted solar heat compared with a specified alternative. Its visible transmission, colour, reflectance and emissivity also need checking. It may be low-e, but the names are not interchangeable; choose using the rated complete make-up and room’s solar exposure.
- Sound Transmission Class (STC)
- A single-number sound-insulation rating based on a specified reference contour and frequency bands. It is useful for comparing rated assemblies but omits some low-frequency behaviour relevant to exterior noise. Equal STC values can conceal different frequency responses and do not predict an occupied room’s exact noise level.
- Spacer
- The edge component maintaining separation between panes in an insulating-glass unit. Its geometry, materials, desiccant arrangement and compatible seals matter. A warm-edge description does not by itself establish the complete edge-system durability, condensation index or installed-window temperature.
- Spatial daylight autonomy (sDA)
- A daylight-analysis metric describing how much of a space meets a stated daylight illuminance criterion for a stated fraction of occupied hours. Geometry, weather, shades and schedules influence the result. It does not by itself establish glare control, view quality, lighting energy or comfort at every workstation.
- Specification schedule
- A structured list defining each opening’s identity, dimensions, operation, glass make-up, performance, finish and relevant installation details. Distinguish approximate planning entries from verified ordering information. It helps prevent a quote or delivery from silently substituting a different product or scope.
- Sputtered coating
- A coating applied through a vacuum-deposition process, often called a soft coat in window discussions. The product’s handling and approved exposed or cavity-facing use govern placement. Do not assume every sputtered coating has the same durability, solar response or allowable glass surface.
- Stool
- The interior shelf-like sill board at the bottom of a window opening, often replaced or trimmed during installation.
- Storefront
- A framed glazed system commonly used at commercial frontages. The manufacturer defines its intended span, height, support and drainage arrangement. It is not interchangeable with curtain wall or residential windows merely because the elevation looks similar; exposure and project requirements need a system-specific review.
- Structural glazing
- A design in which a specified glazing connection, sometimes a structural silicone joint, transfers particular loads. The engineered geometry, materials, testing and quality controls are central. Ordinary weather sealant or a visually similar joint must not be assumed to provide structural support.
- Tempered glass
- Glass processed to create a stress pattern that changes strength and breakage behaviour. Safety-glazing compliance requires the appropriate tested construction and identification; the word tempered alone does not establish every applicable safety, guard, security or impact requirement. Heat-strengthened glass is a different category.
- Thermal break
- A lower-conductivity connection interrupting a conductive path, often between inner and outer metal frame sections. Material, geometry, continuity and assembly design determine its effect. A thermally broken label is not a whole-window U-factor or proof that every perimeter junction is warm.
- Thermal stress
- Stress arising when parts of glass experience different temperatures and cannot expand uniformly. Edge condition, shade patterns, coatings, absorption and mounting can influence risk. Choosing heat treatment or a retrofit film requires the actual make-up and exposure assessment, rather than a general claim that thicker glass solves it.
- Trickle vent
- A small controllable ventilation opening incorporated into or beside an assembly. Its airflow and acoustic behaviour depend on pressure and design. A vent changes the closed-envelope concept and must fit the ventilation strategy; the window’s separate glazing rating does not establish the vented system’s overall behaviour.
- Triple glazing
- Three panes with two cavities in a conventional insulating-glass make-up. Additional panes can support lower heat transfer when the complete design is appropriate, but ratings, solar gain, sound reduction, weight and fit depend on the actual assembly. There is no universal price multiplier.
- U-factor
- Thermal transmittance: heat flow per area per temperature difference under defined conditions, commonly W/m²·K in Canada. Identify whether the value is centre-glass, frame or whole-window. Lower means less rated transmission for the same scope; it does not include a forecast of sunlight, leakage or household bills.
- Vacuum insulating glazing (VIG)
- Glazing using a low-pressure cavity to reduce gas heat transport, commonly with supports and a specialised edge system. Published centre-glass data, product approvals and warranties have specific scopes. Check available dimensions, frame integration, impact requirements, service arrangements and Canadian acceptance for the actual product.
- Vapour retarder
- A material or layer limiting water-vapour diffusion under a defined test method. Its appropriate location depends on climate, assembly and drying strategy. It is not automatically an air barrier; air leakage can carry moisture through discontinuities even where a low-permeance sheet is present.
- Ventilation free area
- The unobstructed area available for airflow after considering the opening geometry, screens and other restrictions. It differs from frame area and emergency-escape clear opening. Area alone does not establish a reliable ventilation rate because pressure, airflow path and controls also matter.
- Visible transmittance (VT)
- The fraction of visible light transmitted under a stated spectral weighting and rating method, expressed as a fraction or percentage. Whole-window VT includes frame effects; glass-only VT has another scope. Higher VT does not alone establish useful room daylight, glare control, privacy or solar heat gain.
- Warranty exclusion
- A condition or event outside a warranty’s promised remedy. Read coverage, remedy, labour, access, transfer, registration and geographic terms as well as duration. A long warranty period does not establish full replacement cost coverage or identify which business handles an installation-related problem.
- Water-resistive barrier (WRB)
- A material or system behind exterior finishes intended to resist liquid-water entry into the protected assembly while managing incidental water. Window flashing must connect to it. Vapour properties and air-control functions vary, so the WRB should not automatically be treated as the vapour retarder or air barrier.
- Weep holes
- Designed drainage openings in a window or wall system. Keep the specified paths clear and check the manufacturer’s detail before adding sealant or drilling. A weep’s location and intended function must be identified; an unexplained hole should not be assumed to be a drainage outlet.
- Wet glazing
- Glazing installed using specified liquid-applied sealant or compound at defined interfaces, in contrast with systems relying primarily on preformed gaskets. The design still needs appropriate support, clearances and drainage. The term does not mean that any exposed sealant can be substituted for the approved system.
- Window wall
- A glazed enclosure system commonly installed between floor slabs or other building boundaries. Its support, perimeter connections and slab-edge interfaces differ from curtain wall. Identify the actual system and project details; names used casually in sales material may not describe its engineered load path.
- Window-to-wall ratio
- The glazed or fenestration area divided by a defined wall area under a stated convention. It helps describe an elevation’s exposure, but the exact boundaries matter. Two façades with the same ratio can have different orientations, frames, shading, daylight and heat transfer.
SOURCESSources and further reading
- NRCan — ENERGY STAR Canada fenestration specification, version 5; programme criteria and scope
- NRCan — Keeping the Heat In, section 8; residential window and enclosure context
- NFRC — Residential ratings; whole-product label scope and different performance quantities
- NFRC — Condensation Index; method distinctions from Condensation Resistance
- NOAA — Saturation-vapour, humidity and dew-point equations; liquid-water relation
- DOE Building Science Education — High-performance window systems: glass; conventional glazing, gas and low-e overview, not Canadian code
- FGIA — Performance-class overview; NAFS designation and pressure versus grade
- ASTM — E1332-22 scope; OITC spectrum, specimen and field limitations
- ASA Standards — Sound Transmission Class; rating definition
- NGA — Heat-treated architectural glass guidance (2022); tempered and heat-strengthened distinctions
- Vitro — Low-e coating placement; manufacturer-specific approved glass surfaces
- ECCC — Bird collisions with glazing; exterior-pattern recommendations and limitations
- IES — ANSI/IES LM-83-23 publisher scope; annual sDA and ASE simulation metrics, not Canadian building code
- Passive House Institute — Component certification; climate and component scope
- Phius — Window and door certification; distinct programme and product data
- Alberta — Prepaid contracting licence; official applicability and exemptions